The ROCKY VIEW COUNTY in Canada from Americas region had released this tender for Request for Proposal Rfp 25-006 professional services for preliminary engineering of the blazer raw water system upgrades This Request for Proposals the RFP is an invitation by Rocky View County the County to prospective proponents to submit proposals for Preliminary Engineering for the Blazer Raw Water System Upgrades located on the bank of Bow River and in the Lynx Ridge Subdivision as further described in Appendix C of this RFP The Blazer raw water intake provides water for irrigation and potable use to a customer base in the Lynx Ridge Watermark area The intake was originally constructed in 1989 consisting of three intake pipes in an infiltration gallery in the Bow River connected to a wet well Three raw water pumps located in the pump house above the wet well connect to a raw water header discharging to the raw water transmission main one 60 horsepower hp low lift pump with a capacity of 28 7 L s and two 40 hp low lift pumps each with a capacity of 18 8 L s The system s as-built drawings indicate the raw water transmission main is a 200 mm 8 diameter C900 PVC pipe rated to 200 psi This raw water pipe extends approximately 1 3 km north from the raw water pumphouse before teeing off to the Lynx Ridge Golf Course LRGC and the water treatment plant WTP Raw water is fed to the LRGC in the summer months for irrigating the golf course and residential lots in the Lynx Ridge community The raw water line running from the tee to the WTP is 100 mm 4 and feeds directly into the treatment process there is no raw holding cell for potable water generation between the raw water intake and the WTP With respect to the Blazer raw water intake and pumphouse Major issues with the infiltration intake pipes limiting the capacity of the raw water supply have been identified A previous status report indicated that the infiltration gallery was blinded off during the 2013 flood event As a temporary measure to maintain the raw water supply electrical upgrades were completed to allow for in-river pumps with fish screens to be installed in the Bow River to pump water into the wet well each with a capacity of 25 L s At present two in-river pumps are used during months of high demand May-September and one in-river pump is used during months of lower demand October-April The existing system presents health and safety concerns with operator access to the in-river pumps Further it is observed that the wet well infiltration gallery is not fully isolated from the river such that the in-river pumps cannot always maintain a consistent wet well level Hydraulic constraints affect the efficient operation of the 60 hp low lift pump Levels and flows need to be monitored closely to maintain the functionality of the 60-hp pump Further review of the existing raw water system and intakes is required with a review of options for upgrading to a permanent system With respect to the Blazer raw water transmission line Since the County purchased the Blazer System in 2022 there have been two catastrophic raw water transmission line breaks As there is no raw water storage at the WTP or transmission line redundancy the potable water supply depleted significantly while emergency repairs were completed At the tee connection where the pipe diameter reduces to 100mm the pipe material is not completely certain and it is also not certain what the pressure rating is on this segment of line Build-out projections for the service area will require an upsize in the pipe for this segment tee to WTP Considering the current condition age and alignment of the existing raw water transmission line further review and potential pipe alignment options for a second raw water transmission line is required with options for alignment and ability to provide redundancy with tender notice no. AB-2025-02385 published on 03 Apr 2025. The tender expired on 24 Apr 2025. This tender is sourced from Purchasing and is eligible for suppliers interested in Riverbank protection works. Interested bidders can obtain further information including complete bid documents or ways to participate by registering on Tender Impulse and referencing via Tender Impulse ID 7509937.
*The deadline for this tender has passed.
Tender Notice No:
AB-2025-02385
Tender Organisation:
ROCKY VIEW COUNTY
Tender Sector:
Tender Service:
Worldwide
Tender Region:
Tender Country:
Tender CPV:
45246200 : Riverbank protection works
Tender Source:
Purchasing
Tender Document Type:
Tender Notice
Tender Description:
Request for Proposal Rfp 25-006 professional services for preliminary engineering of the blazer raw water system upgrades This Request for Proposals the RFP is an invitation by Rocky View County the County to prospective proponents to submit proposals for Preliminary Engineering for the Blazer Raw Water System Upgrades located on the bank of Bow River and in the Lynx Ridge Subdivision as further described in Appendix C of this RFP The Blazer raw water intake provides water for irrigation and potable use to a customer base in the Lynx Ridge Watermark area The intake was originally constructed in 1989 consisting of three intake pipes in an infiltration gallery in the Bow River connected to a wet well Three raw water pumps located in the pump house above the wet well connect to a raw water header discharging to the raw water transmission main one 60 horsepower hp low lift pump with a capacity of 28 7 L s and two 40 hp low lift pumps each with a capacity of 18 8 L s The system s as-built drawings indicate the raw water transmission main is a 200 mm 8 diameter C900 PVC pipe rated to 200 psi This raw water pipe extends approximately 1 3 km north from the raw water pumphouse before teeing off to the Lynx Ridge Golf Course LRGC and the water treatment plant WTP Raw water is fed to the LRGC in the summer months for irrigating the golf course and residential lots in the Lynx Ridge community The raw water line running from the tee to the WTP is 100 mm 4 and feeds directly into the treatment process there is no raw holding cell for potable water generation between the raw water intake and the WTP With respect to the Blazer raw water intake and pumphouse Major issues with the infiltration intake pipes limiting the capacity of the raw water supply have been identified A previous status report indicated that the infiltration gallery was blinded off during the 2013 flood event As a temporary measure to maintain the raw water supply electrical upgrades were completed to allow for in-river pumps with fish screens to be installed in the Bow River to pump water into the wet well each with a capacity of 25 L s At present two in-river pumps are used during months of high demand May-September and one in-river pump is used during months of lower demand October-April The existing system presents health and safety concerns with operator access to the in-river pumps Further it is observed that the wet well infiltration gallery is not fully isolated from the river such that the in-river pumps cannot always maintain a consistent wet well level Hydraulic constraints affect the efficient operation of the 60 hp low lift pump Levels and flows need to be monitored closely to maintain the functionality of the 60-hp pump Further review of the existing raw water system and intakes is required with a review of options for upgrading to a permanent system With respect to the Blazer raw water transmission line Since the County purchased the Blazer System in 2022 there have been two catastrophic raw water transmission line breaks As there is no raw water storage at the WTP or transmission line redundancy the potable water supply depleted significantly while emergency repairs were completed At the tee connection where the pipe diameter reduces to 100mm the pipe material is not completely certain and it is also not certain what the pressure rating is on this segment of line Build-out projections for the service area will require an upsize in the pipe for this segment tee to WTP Considering the current condition age and alignment of the existing raw water transmission line further review and potential pipe alignment options for a second raw water transmission line is required with options for alignment and ability to provide redundancy
Tender Bidding Type:
Tender Document:
Looking for more tenders like this one in Riverbank protection works? With over 11 million global procurement opportunities and new tenders added daily, Tender Impulse is your gateway to international and local contracting success. Whether you're targeting the Infrastructure and construction sector in Canada, or expanding across regions, we provide live, accurate, and relevant updates every day.
Our platform sources tenders from:
Every day, we add hundreds of new RFPs, RFQs, EOIs, and contract awards across multiple sectors and geographies. This tender from Canada is just a sample of what's available right now.
Tender Impulse covers:
Each listing is categorized using CPV codes like 45246200, enabling precise filtering. Search by:
While you're viewing a tender in Canada, Tender Impulse offers access to tenders across:
Tender Impulse provides more than listings:
Thousands of new tenders are added daily-across countries, sectors, and CPV codes. With Tender Impulse, you gain strategic insight, timely alerts, and a competitive edge.
Request a free live demo now to unlock tenders customized to your Infrastructure and construction, Canada, and Riverbank protection works categories.
The tender has been issued by ROCKY VIEW COUNTY in Canada. Such a type of tender falls under Riverbank protection works, within the Infrastructure and construction Tenders sector, and is listed on Tender Impulse under notice number AB-2025-02385.
The notice was published on 03 Apr 2025 and submissions close on 24 Apr 2025. Late bids are rarely accepted in public procurement, so aim to have your documents ready several days before the closing date.
It is classified under CPV codes 45246200, which correspond to Riverbank protection works. If your company supplies these products or services, these are the codes to save in your alert profile so no matching tender passes you by.
No - and this matters. Tender Impulse is a tender aggregation and alert service: we collect procurement notices from official sources around the world and list them in one place. We do not receive, forward or evaluate bids. Your bid for this tender must be submitted directly to ROCKY VIEW COUNTY, using the method described in the original tender document, before 24 Apr 2025. Tender Impulse provides complete assistance in submitting all bids posted on its website.
Request a live demo on Tender Impulse and our tender experts will walk you through this listing, share the available documents, and explain how to submit your bid to ROCKY VIEW COUNTY. Subscribers also receive help with registration requirements and, where needed, translation of non-English notices - but the submission itself always goes from you to the buyer.
There are currently 6841 live tenders of 169632 total tenders from Canada on Tender Impulse. You can browse them on our Canada tenders page, or save a search combining Canada with CPV codes {full_cpv_codes} - we will then email you every new match on the day it is published.
Suppliers must verify technical specifications, the delivery schedules and any other intrinsic details as provided in the complete bid documents before deciding to submit their bids. All necessary certifications and supplier registrations must be undertaken before participation.
The procurement is applicable to companies in the Riverbank protection works and related industries. If you belong to this industry, you can review the technical documents before assessing your relevance to your company.
The public procurement trends for Rfp 25-006 professional services for preliminary engineering of the blazer raw water system upgrades can be assessed by viewing historical data and buying patterns for this product. Subscribed members can view and even download reports of tenders released in the past for their market research. This shall allow them to carefully prepare a compelling bid.
Your action completed successfully.