The Municipal Council in India from Asian region had released this tender for Electrical work in municipal area Deogarh - Wiring of light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq. mm nominal size FR PVC insulated unsheathed flexible copper conductor 1.1 kV grade and 1.5 sq. mm nominal size FR PVC insulated unsheathed flexible copper earth conductor 1.1 kV grade (IS:694) on surface ISI marked ( IS:14927 P - II ) virgin material UPVC trunking & it's accessories, Hot Dipped Galvanized Modular box of 1.2 mm thick with earth terminal/ Surface Moulded virgin material UPVC Modular Box , 10 A Modular switch, Modular face plate with grid plate, 3 pin ceiling rose/holder /3 way Connector, screws, making connections, testing etc. as required. For specification of copper Conductor, Phenolic Laminated sheet's & Electrical/ Wiring accessories refer Chapter-53, 54 & 56 for additional technical parameters of product / work refer Annexure 'A' attached with this BSR, Short point (up to 3 mtr.), Medium point (up to 6 mtr.), Long point (up to 10 mtr.), Wiring of twin control light point with 1.5 sq. mm nominal size FR PVC insulated unsheathed flexible copper conductor 1.1 kV grade and 1.5 sq. mm nominal size FR PVC insulated unsheathed flexible copper earth conductor 1.1 kV grade (IS:694) of approved make on surface ISI marked ( IS:14927 P - II ) virgin material UPVC trunking & it's accessories, Hot Dipped Galvanized Modular box of 1.2 mm thick with earth terminal/ Surface 2 No. Moulded virgin material UPVC Modular Box , 2 Nos 10 A two way Modular switch, 3 pin ceiling rose / holder/3 way Connector , Modular face plate with grid plate, screws, making connections, testing etc. as required. For specification of copper Conductor, Phenolic Laminated sheet's & Electrical/ Wiring accessories refer Chapter-53, 54 & 56 for additional technical parameters of product / work refer Annexure 'A' attached with this BSR, Short point (up to 3 mtr.), Medium point (up to 6 mtr.), Long point (up to 10 mtr..), Wiring of 3/5 pin 6 amp. Light plug point with 1.5 sq. mm nominal size FR PVC insulated unsheathed flexible copper conductor 1.1 kV grade and 1.5 sq. mm nominal size FR PVC insulated unsheathed flexible copper earth conductor 1.1 kV grade(IS:694) on surface ISI marked ( IS:14927 P - II ) virgin material UPVC Trunking & it's accessories, Hot Dipped Galvanized Modular box of 1.2 mm thick with earth terminal/ Surface Moulded virgin material UPVC Modular Box, modular 10A switch, 3/5 pin 6 A modular socket, Modular face plate with grid plate, screws, making connections, testing etc. as required. For specification of copper Conductor, Phenolic Laminated sheet's & Electrical/ Wiring accessories refer Chapter-53, 54 & 56 for additional technical parameters of product / work refer Annexure 'A' attached with this BSR, On board, Short point (up to 3 mtr.), Medium point (up to 6 mtr.), Long point (up to 10 mtr..), "Supplying and drawing FR PVC insulated & unsheathed flexible, copper conductor as per PWD specification for electrical Works with ISI marked (IS:694) and as per IS 8130 : 2013 of 1.1 kV grade . Wire should be made from 99.90 % purity copper, class 5 stranding in acc. to IS:8130/IEC 60228 for lower watt loss , oxygen free for less chances of oxidization, insulation PVC type A/C/D , flame retardant as per IS 10810-53, better amperage rating as per IS:3961 part 5, in existing surface or recessed PVC/ MS conduit/casing capping making connections with Copper Lugs of suitable size, Ferrules, testing etc. as required. OEM Must have its own in house NABL lab setup for all testing facilities for wires. For additional technical parameters of product / work refer Annexure 'A' attached with this BSR", 2 x 1.5 sq.mm, 3x 1.5 sq.mm, 3 x 2.5 sq.mm, Supply and laying speaker cable of IS/ISO 9001 CERTIFIED COMPANY made following size 2 core twin twisted multi stranded electrolytic grade copper conductor, overall PVC insulated and armoured cable (Blue colour) on surface/ above false ceiling including cost of GI spacers, saddles etc. as required. For additional technical parameters of product / work refer Annexure 'A' attached with this BSR, 1.5 Sq.mm, 2.5 Sq.mm, Providing & Fixing of 240/415 V AC MCB with positive isolation of 10 kA breaking capacity (B/ C/D tripping characteristic as per type of load and site requirement) 4 KV impulse withstand voltage, ISI marked IS 8828(1996) / conforming to IEC 60898-1 2002, IEC 60947-2, low watt losses, trip free mechanisum , energy limiting of class 3 as per IEC, minimum phase termination capacity of 35sq.mm. , conductor line load reversibility , IP 20 contact protection and fitted in existing distribution board/sheets, minimum electrical operation 20, 000 upto 20 A rating and 10, 000 upto 63 A, 5000 for 80 A & above rating including making connections, testing etc. as required. OEM shall have submit NABL / CPRI / ERDA accrediated lab type test reports & All as per pre approved by Engineer incharge. For additional technical parameters of product / work refer Annexure 'A' attached with this BSR, 6 A to 32 A rating, "Double pole MCB(With B/C curve tripping Characteristics), 6 A to 32 A rating", "Triple pole MCB (With B/C curve trippingCharacteristics), 6 A to 32 A rating", "Four pole MCB (With B/C curve tripping Characteristics), 6 A to 32 A rating", "Triple pole MCB (With D curve tripping Characteristics), 6 A to 32 A rating", "Providing & Fixing of 240/415 V isolator ISI marked IS:13947-II/conforming to IEC 60947-3, suitable for AC22A utilization category, 4KV impulse withstand voltage, true contact indication, Red colour dolly / lever shall have single mould covering overall poles for operation , two position din rail mounting, minimum phase termination capacity of 35sq.mm. IP 20 contact protection and fitted in existing distribution board / sheet including making connections, testing etc. as required. OEM shall have submit NABL / CPRI / ERDA accrediated lab type test reports & All as per pre approved by Engineer in-charge.For additional technical parameters of product / work refer Annexure 'A' attached with this BS , Double pole isolator", 63 A rating, "Triple pole Isolator, 63 A rating", "Four pole Isolator, 63 A rating", Providing & Fixing of 240/415 V factory fitted RCBO with overload, short-circuit and earth leakage protection with ISI marked (IS12640- 2)/ conforming to IEC 61009-1, breaking capacity 10 KA, provision for pad lock, min. Electrical operation 10, 000 upto 63 A rating , minimum phase termination capacity of 35sq.mm. , IP 20 contact protection with existing distribution board / sheet including making connections, testing etc. as required. OEM shall have submit NABL / CPRI / ERDA accrediated lab type test reports & All as per pre approved by Engineer in-charge. For additional technical parameters of product / work refer Annexure 'A' attached with this BSR, "Two pole 30 mA sensitivity, 6A-32 A rating", "Two pole 100/300mA sensitivity, 6A-32 A rating", P&F 240/415 V AC Change Over Miniature circuit breaker with three positions (I-O-II) which allows supply change over from one source to second source & vice- versa, conforming to IS/ IEC 60947-3 in existing board/sheets including making connections, testing etc. as required. OEM shall have submit NABL / CPRI / ERDA accrediated lab type test reports & All as per pre approved by Engineer incharge.For additional technical parameters of product / work refer Annexure 'A' attached with this BSR, 63 Amp, 3 Module, Providing & Fixing of 240/415 V Residual current circuit breaker (RCCB) conforming to (IS:12640-1)/ IEC 61008 -1 , rated 4 KV impulse withstand voltage truly current operated and shall operate on CBCT mechanisum, provision for pad lock, min. operation 10, 000 upto 63 A rating and 5000 for 100 A rating and minimum phase termination capacity of 35 sq.mm. rigid wire , IP 20 contact protection with existing distribution board / sheet including making connections, testing etc. as required. OEM shall have submit NABL / CPRI / ERDA accrediated lab type tes at Rajsamand,Rajasthan,India with tender notice no. 2025_DLB_456928_10 published on 09 Apr 2025. The tender expired on 28 Apr 2025. This tender is sourced from Official Website and is eligible for suppliers interested in Conductors domestic. Interested bidders can obtain further information including complete bid documents or ways to participate by registering on Tender Impulse and referencing via Tender Impulse ID 7578671.
*The deadline for this tender has passed.
Tender Notice No:
2025_DLB_456928_10
Tender Organisation:
Municipal Council
Tender Sector:
Tender Service:
Worldwide
Tender Region:
Tender Country:
Tender CPV:
44318001 : Conductors domestic
Tender Document Type:
Tender Notice
Tender Description:
Electrical work in municipal area Deogarh - Wiring of light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq. mm nominal size FR PVC insulated unsheathed flexible copper conductor 1.1 kV grade and 1.5 sq. mm nominal size FR PVC insulated unsheathed flexible copper earth conductor 1.1 kV grade (IS:694) on surface ISI marked ( IS:14927 P - II ) virgin material UPVC trunking & it's accessories, Hot Dipped Galvanized Modular box of 1.2 mm thick with earth terminal/ Surface Moulded virgin material UPVC Modular Box , 10 A Modular switch, Modular face plate with grid plate, 3 pin ceiling rose/holder /3 way Connector, screws, making connections, testing etc. as required. For specification of copper Conductor, Phenolic Laminated sheet's & Electrical/ Wiring accessories refer Chapter-53, 54 & 56 for additional technical parameters of product / work refer Annexure 'A' attached with this BSR, Short point (up to 3 mtr.), Medium point (up to 6 mtr.), Long point (up to 10 mtr.), Wiring of twin control light point with 1.5 sq. mm nominal size FR PVC insulated unsheathed flexible copper conductor 1.1 kV grade and 1.5 sq. mm nominal size FR PVC insulated unsheathed flexible copper earth conductor 1.1 kV grade (IS:694) of approved make on surface ISI marked ( IS:14927 P - II ) virgin material UPVC trunking & it's accessories, Hot Dipped Galvanized Modular box of 1.2 mm thick with earth terminal/ Surface 2 No. Moulded virgin material UPVC Modular Box , 2 Nos 10 A two way Modular switch, 3 pin ceiling rose / holder/3 way Connector , Modular face plate with grid plate, screws, making connections, testing etc. as required. For specification of copper Conductor, Phenolic Laminated sheet's & Electrical/ Wiring accessories refer Chapter-53, 54 & 56 for additional technical parameters of product / work refer Annexure 'A' attached with this BSR, Short point (up to 3 mtr.), Medium point (up to 6 mtr.), Long point (up to 10 mtr..), Wiring of 3/5 pin 6 amp. Light plug point with 1.5 sq. mm nominal size FR PVC insulated unsheathed flexible copper conductor 1.1 kV grade and 1.5 sq. mm nominal size FR PVC insulated unsheathed flexible copper earth conductor 1.1 kV grade(IS:694) on surface ISI marked ( IS:14927 P - II ) virgin material UPVC Trunking & it's accessories, Hot Dipped Galvanized Modular box of 1.2 mm thick with earth terminal/ Surface Moulded virgin material UPVC Modular Box, modular 10A switch, 3/5 pin 6 A modular socket, Modular face plate with grid plate, screws, making connections, testing etc. as required. For specification of copper Conductor, Phenolic Laminated sheet's & Electrical/ Wiring accessories refer Chapter-53, 54 & 56 for additional technical parameters of product / work refer Annexure 'A' attached with this BSR, On board, Short point (up to 3 mtr.), Medium point (up to 6 mtr.), Long point (up to 10 mtr..), "Supplying and drawing FR PVC insulated & unsheathed flexible, copper conductor as per PWD specification for electrical Works with ISI marked (IS:694) and as per IS 8130 : 2013 of 1.1 kV grade . Wire should be made from 99.90 % purity copper, class 5 stranding in acc. to IS:8130/IEC 60228 for lower watt loss , oxygen free for less chances of oxidization, insulation PVC type A/C/D , flame retardant as per IS 10810-53, better amperage rating as per IS:3961 part 5, in existing surface or recessed PVC/ MS conduit/casing capping making connections with Copper Lugs of suitable size, Ferrules, testing etc. as required. OEM Must have its own in house NABL lab setup for all testing facilities for wires. For additional technical parameters of product / work refer Annexure 'A' attached with this BSR", 2 x 1.5 sq.mm, 3x 1.5 sq.mm, 3 x 2.5 sq.mm, Supply and laying speaker cable of IS/ISO 9001 CERTIFIED COMPANY made following size 2 core twin twisted multi stranded electrolytic grade copper conductor, overall PVC insulated and armoured cable (Blue colour) on surface/ above false ceiling including cost of GI spacers, saddles etc. as required. For additional technical parameters of product / work refer Annexure 'A' attached with this BSR, 1.5 Sq.mm, 2.5 Sq.mm, Providing & Fixing of 240/415 V AC MCB with positive isolation of 10 kA breaking capacity (B/ C/D tripping characteristic as per type of load and site requirement) 4 KV impulse withstand voltage, ISI marked IS 8828(1996) / conforming to IEC 60898-1 2002, IEC 60947-2, low watt losses, trip free mechanisum , energy limiting of class 3 as per IEC, minimum phase termination capacity of 35sq.mm. , conductor line load reversibility , IP 20 contact protection and fitted in existing distribution board/sheets, minimum electrical operation 20, 000 upto 20 A rating and 10, 000 upto 63 A, 5000 for 80 A & above rating including making connections, testing etc. as required. OEM shall have submit NABL / CPRI / ERDA accrediated lab type test reports & All as per pre approved by Engineer incharge. For additional technical parameters of product / work refer Annexure 'A' attached with this BSR, 6 A to 32 A rating, "Double pole MCB(With B/C curve tripping Characteristics), 6 A to 32 A rating", "Triple pole MCB (With B/C curve trippingCharacteristics), 6 A to 32 A rating", "Four pole MCB (With B/C curve tripping Characteristics), 6 A to 32 A rating", "Triple pole MCB (With D curve tripping Characteristics), 6 A to 32 A rating", "Providing & Fixing of 240/415 V isolator ISI marked IS:13947-II/conforming to IEC 60947-3, suitable for AC22A utilization category, 4KV impulse withstand voltage, true contact indication, Red colour dolly / lever shall have single mould covering overall poles for operation , two position din rail mounting, minimum phase termination capacity of 35sq.mm. IP 20 contact protection and fitted in existing distribution board / sheet including making connections, testing etc. as required. OEM shall have submit NABL / CPRI / ERDA accrediated lab type test reports & All as per pre approved by Engineer in-charge.For additional technical parameters of product / work refer Annexure 'A' attached with this BS , Double pole isolator", 63 A rating, "Triple pole Isolator, 63 A rating", "Four pole Isolator, 63 A rating", Providing & Fixing of 240/415 V factory fitted RCBO with overload, short-circuit and earth leakage protection with ISI marked (IS12640- 2)/ conforming to IEC 61009-1, breaking capacity 10 KA, provision for pad lock, min. Electrical operation 10, 000 upto 63 A rating , minimum phase termination capacity of 35sq.mm. , IP 20 contact protection with existing distribution board / sheet including making connections, testing etc. as required. OEM shall have submit NABL / CPRI / ERDA accrediated lab type test reports & All as per pre approved by Engineer in-charge. For additional technical parameters of product / work refer Annexure 'A' attached with this BSR, "Two pole 30 mA sensitivity, 6A-32 A rating", "Two pole 100/300mA sensitivity, 6A-32 A rating", P&F 240/415 V AC Change Over Miniature circuit breaker with three positions (I-O-II) which allows supply change over from one source to second source & vice- versa, conforming to IS/ IEC 60947-3 in existing board/sheets including making connections, testing etc. as required. OEM shall have submit NABL / CPRI / ERDA accrediated lab type test reports & All as per pre approved by Engineer incharge.For additional technical parameters of product / work refer Annexure 'A' attached with this BSR, 63 Amp, 3 Module, Providing & Fixing of 240/415 V Residual current circuit breaker (RCCB) conforming to (IS:12640-1)/ IEC 61008 -1 , rated 4 KV impulse withstand voltage truly current operated and shall operate on CBCT mechanisum, provision for pad lock, min. operation 10, 000 upto 63 A rating and 5000 for 100 A rating and minimum phase termination capacity of 35 sq.mm. rigid wire , IP 20 contact protection with existing distribution board / sheet including making connections, testing etc. as required. OEM shall have submit NABL / CPRI / ERDA accrediated lab type tes at Rajsamand,Rajasthan,India
Tender Bidding Type:
Tender Document:
Looking for more tenders like this one in Conductors domestic? With over 11 million global procurement opportunities and new tenders added daily, Tender Impulse is your gateway to international and local contracting success. Whether you're targeting the Infrastructure and construction sector in India, or expanding across regions, we provide live, accurate, and relevant updates every day.
Our platform sources tenders from:
Every day, we add hundreds of new RFPs, RFQs, EOIs, and contract awards across multiple sectors and geographies. This tender from India is just a sample of what's available right now.
Tender Impulse covers:
Each listing is categorized using CPV codes like 44318001, enabling precise filtering. Search by:
While you're viewing a tender in India, Tender Impulse offers access to tenders across:
Tender Impulse provides more than listings:
Thousands of new tenders are added daily-across countries, sectors, and CPV codes. With Tender Impulse, you gain strategic insight, timely alerts, and a competitive edge.
Request a free live demo now to unlock tenders customized to your Infrastructure and construction, India, and Conductors domestic categories.
The tender has been issued by Municipal Council in India. Such a type of tender falls under Conductors domestic, within the Infrastructure and construction Tenders sector, and is listed on Tender Impulse under notice number 2025DLB45692810.
The notice was published on 09 Apr 2025 and submissions close on 28 Apr 2025. Late bids are rarely accepted in public procurement, so aim to have your documents ready several days before the closing date.
It is classified under CPV codes 44318001, which correspond to Conductors domestic. If your company supplies these products or services, these are the codes to save in your alert profile so no matching tender passes you by.
No - and this matters. Tender Impulse is a tender aggregation and alert service: we collect procurement notices from official sources around the world and list them in one place. We do not receive, forward or evaluate bids. Your bid for this tender must be submitted directly to Municipal Council, using the method described in the original tender document, before 28 Apr 2025. Tender Impulse provides complete assistance in submitting all bids posted on its website.
Request a live demo on Tender Impulse and our tender experts will walk you through this listing, share the available documents, and explain how to submit your bid to Municipal Council. Subscribers also receive help with registration requirements and, where needed, translation of non-English notices - but the submission itself always goes from you to the buyer.
There are currently 13460 live tenders of 490580 total tenders from India on Tender Impulse. You can browse them on our India tenders page, or save a search combining India with CPV codes {full_cpv_codes} - we will then email you every new match on the day it is published.
Suppliers must verify technical specifications, the delivery schedules and any other intrinsic details as provided in the complete bid documents before deciding to submit their bids. All necessary certifications and supplier registrations must be undertaken before participation.
The procurement is applicable to companies in the Conductors domestic and related industries. If you belong to this industry, you can review the technical documents before assessing your relevance to your company.
The public procurement trends for Electrical work in municipal area Deogarh - Wiring of light point fan point exhaust fan point call bell point with 1.5 sq. mm nominal size FR PVC insulated unsheathed flexible copper conductor 1.1 kV grade and 1.5 sq. mm nominal size FR PVC insulated unsheathed flexible copper earth conductor 1.1 kV grade (IS694) on surface ISI marked ( IS14927 P - II ) virgin material UPVC trunking it's accessories, Hot Dipped Galvanized Modular box of 1.2 mm thick with earth terminal Surface Moulded virgin material UPVC Modular Box , 10 A Modular switch, Modular face plate with grid plate, 3 pin ceiling roseholder 3 way Connector, screws, making connections, testing etc. as required. For specification of copper Conductor, Phenolic Laminated sheet's Electrical Wiring accessories refer Chapter-53, 54 56 for additional technical parameters of product work refer Annexure 'A' attached with this BSR, Short point (up to 3 mtr.), Medium point (up to 6 mtr.), Long point (up to 10 mtr.), Wiring of twin cont.. can be assessed by viewing historical data and buying patterns for this product. Subscribed members can view and even download reports of tenders released in the past for their market research. This shall allow them to carefully prepare a compelling bid.