Tender Summary
The Kent State University - Office of the University Architect in USA from Americas region has released this tender for Stewart Hall VRF System Replacement Stewart Hall was constructed in approximately 1967 as a small group residential housing and dining facility. It was renovated in 2010-2011 for administrative/office functions when the current HVAC systems were installed. The two (2) VRF systems installed at that time have reached the end of their beneficial service life and need to be replaced in their entirety. We expect the RTU with VAV/RH terminals, heating water system and equipment, and the 100% OA/EA HRU to remain in place and in service during this project. The existing VRF systems consist of (2) outdoor units with twinned outdoor equipment, 3 branch controllers, and 47 total indoor units. Both complete systems need to be replaced, including the outdoor units, branch controllers, indoor units, equipment supports, controllers, and all refrigerant piping. Control and power wiring and condensate drain piping may be possible to re-use. The current VRF systems serve approximately 14,700 square feet of the building’s roughly 23,000 square feet (net). When originally installed, adequate nitrogen purge was not provided and debris and moisture has fouled compressors and refrigerant control components. The system has also experienced failures of check valves and linear expansion valves. The combination of debris, compressor failures, and refrigerant valve failures, paired with equipment that relies on load diversity, have left KSU with a system that is no longer able to provide adequate heating and cooling to the interior spaces and occupants. We would like to replace the existing VRF systems with new VRF systems due to the tight floor to floor heights available and the unavailable location for chillers and piping and pumping equipment. The new systems will keep the current at-grade location of the outdoor units, and will re-use the indoor unit and refrigerant valving locations with similar equipment. The new systems should also not rely on diversity of load; the outdoor units should have the same nominal capacity as the sum of the connected indoor units’ capacities to the greatest extent possible. Re-use of the existing electrical feeders is expected. New outdoor units shall operate individually, not be twinned or paired together, and shall serve a single refrigerant valving unit and associated indoor units. New VRF system controls shall be provided. New interface controllers will be required between the VRF system and KSU’s Johnson Controls BAS. Removal and replacement of any and all wall, floor, and ceiling materials is expected to occur under this project; this is expected to occur to accommodate replacement of all refrigerant piping/insulation and control wiring. Interested parties may attend a pre-proposal meeting on December 8 2026, at 9 am in Room 102 Harbourt Hall, 615 Loop Road, Kent, Ohio 44242. with tender notice no. BIDEXPRESS-COM-KSU-27S034-49945 published on 12 Nov 2026. The tender is due to expire on 18 Dec 2026. This tender is sourced from Bid Express and is eligible for suppliers interested in Central-heating equipment, Heat-exchange units, air-conditioning and refrigerating equipment, and filtering machinery, Heating, ventilation and air-conditioning installation work, Installation work of refrigeration equipment, Building Management Systems. Interested bidders can obtain further information including complete bid documents or ways to participate by registering on Tender Impulse and referencing via Tender Impulse ID 16389056.
Tender Details
Tender NoticeTI Ref: 16389056
Tender Notice No
BIDEXPRESS-COM-KSU-27S034-49945
Tender Organisation
Kent State University - Office of the University Architect
Tender CPV
39715210 : Central-heating equipment42510000 : Heat-exchange units, air-conditioning and refrigerating equipment, and filtering machinery45331000 : Heating, ventilation and air-conditioning installation work45331231 : Installation work of refrigeration equipment42961101 : Building Management Systems
Tender Document Type
Tender Notice
Tender Deadline
18 Dec 2026 31 days left
Tender Description
Stewart Hall VRF System Replacement Stewart Hall was constructed in approximately 1967 as a small group residential housing and dining facility. It was renovated in 2010-2011 for administrative/office functions when the current HVAC systems were installed. The two (2) VRF systems installed at that time have reached the end of their beneficial service life and need to be replaced in their entirety. We expect the RTU with VAV/RH terminals, heating water system and equipment, and the 100% OA/EA HRU to remain in place and in service during this project. The existing VRF systems consist of (2) outdoor units with twinned outdoor equipment, 3 branch controllers, and 47 total indoor units. Both complete systems need to be replaced, including the outdoor units, branch controllers, indoor units, equipment supports, controllers, and all refrigerant piping. Control and power wiring and condensate drain piping may be possible to re-use. The current VRF systems serve approximately 14,700 square feet of the building’s roughly 23,000 square feet (net). When originally installed, adequate nitrogen purge was not provided and debris and moisture has fouled compressors and refrigerant control components. The system has also experienced failures of check valves and linear expansion valves. The combination of debris, compressor failures, and refrigerant valve failures, paired with equipment that relies on load diversity, have left KSU with a system that is no longer able to provide adequate heating and cooling to the interior spaces and occupants. We would like to replace the existing VRF systems with new VRF systems due to the tight floor to floor heights available and the unavailable location for chillers and piping and pumping equipment. The new systems will keep the current at-grade location of the outdoor units, and will re-use the indoor unit and refrigerant valving locations with similar equipment. The new systems should also not rely on diversity of load; the outdoor units should have the same nominal capacity as the sum of the connected indoor units’ capacities to the greatest extent possible. Re-use of the existing electrical feeders is expected. New outdoor units shall operate individually, not be twinned or paired together, and shall serve a single refrigerant valving unit and associated indoor units. New VRF system controls shall be provided. New interface controllers will be required between the VRF system and KSU’s Johnson Controls BAS. Removal and replacement of any and all wall, floor, and ceiling materials is expected to occur under this project; this is expected to occur to accommodate replacement of all refrigerant piping/insulation and control wiring. Interested parties may attend a pre-proposal meeting on December 8 2026, at 9 am in Room 102 Harbourt Hall, 615 Loop Road, Kent, Ohio 44242.
Frequently Asked Questions About This Tender
Who has issued this tender, and what is it for?
The tender has been issued by Kent State University - Office of the University Architect in USA. Such a type of tender falls under Central-heating equipment, Heat-exchange units, air-conditioning and refrigerating equipment, and filtering machinery, Heating, ventilation and air-conditioning installation work, Installation work of refrigeration equipment, Building Management Systems, within the Infrastructure and construction sector, and is listed on Tender Impulse under notice number BIDEXPRESS-COM-KSU-27S034-49945.
What are the key dates for this tender?
The notice was published on 12 Nov 2026 and submissions close on 18 Dec 2026. Late bids are rarely accepted in public procurement, so aim to have your documents ready several days before the closing date.
Which CPV codes apply to this tender?
It is classified under CPV codes 39715210, 42510000, 45331000, 45331231, 42961101, which correspond to Central-heating equipment, Heat-exchange units, air-conditioning and refrigerating equipment, and filtering machinery, Heating, ventilation and air-conditioning installation work, Installation work of refrigeration equipment, Building Management Systems. If your company supplies these products or services, these are the codes to save in your alert profile so no matching tender passes you by.
Can I submit my bid for this tender to Tender Impulse?
No - and this matters. Tender Impulse is a tender aggregation and alert service: we collect procurement notices from official sources around the world and list them in one place. We do not receive, forward or evaluate bids. Your bid for this tender must be submitted directly to Kent State University - Office of the University Architect, using the method described in the original tender document, before 18 Dec 2026. Tender Impulse provides complete assistance in submitting all bids posted on its website.
How do I get the bid documents and participation details?
Request a live demo on Tender Impulse and our tender experts will walk you through this listing, share the available documents, and explain how to submit your bid to Kent State University - Office of the University Architect. Subscribers also receive help with registration requirements and, where needed, translation of non-English notices - but the submission itself always goes from you to the buyer.
How can I find more tenders like this in USA?
There are currently 16510 live tenders of 718168 total tenders from USA on Tender Impulse. You can browse them on our USA tenders page, or save a search combining USA with CPV codes 39715210, 42510000, 45331000, 45331231, 42961101 - we will then email you every new match on the day it is published.
How to prepare for this bid?
Suppliers must verify technical specifications, the delivery schedules and any other intrinsic details as provided in the complete bid documents before deciding to submit their bids. All necessary certifications and supplier registrations must be undertaken before participation.
Is this tender beneficial for me?
The procurement is applicable to companies in the Central-heating equipment, Heat-exchange units, air-conditioning and refrigerating equipment, and filtering machinery, Heating, ventilation and air-conditioning installation work, Installation work of refrigeration equipment, Building Management Systems and related industries. If you belong to this industry, you can review the technical documents before assessing your relevance to your company.
What is the procurement trend for Stewart Hall VRF System Replacement Stewart Hall was constructed in approximately 1967 as a small group residential housing and dining facility. It was renovated in 2010-2011 for administrativeoffice functions when the current HVAC systems were installed. The two (2) VRF systems installed at that time have reached the end of their beneficial service life and need to be replaced in their entirety. We expect the RTU with VAVRH terminals, heating water system and equipment, and the 100 OAEA HRU to remain in place and in service during this project. The existing VRF systems consist of (2) outdoor units with twinned outdoor equipment, 3 branch controllers, and 47 total indoor units. Both complete systems need to be replaced, including the outdoor units, branch controllers, indoor units, equipment supports, controllers, and all refrigerant piping. Control and power wiring and condensate drain piping may be possible to re-use. The current VRF systems serve approximately 14,700 square feet ..?
The public procurement trends for Stewart Hall VRF System Replacement Stewart Hall was constructed in approximately 1967 as a small group residential housing and dining facility. It was renovated in 2010-2011 for administrativeoffice functions when the current HVAC systems were installed. The two (2) VRF systems installed at that time have reached the end of their beneficial service life and need to be replaced in their entirety. We expect the RTU with VAVRH terminals, heating water system and equipment, and the 100 OAEA HRU to remain in place and in service during this project. The existing VRF systems consist of (2) outdoor units with twinned outdoor equipment, 3 branch controllers, and 47 total indoor units. Both complete systems need to be replaced, including the outdoor units, branch controllers, indoor units, equipment supports, controllers, and all refrigerant piping. Control and power wiring and condensate drain piping may be possible to re-use. The current VRF systems serve approximately 14,700 square feet .. can be assessed by viewing historical data and buying patterns for this product. Subscribed members can view and even download reports of tenders released in the past for their market research. This shall allow them to carefully prepare a compelling bid.
Explore More Central-heating equipment, Heat-exchange units, air-conditioning and refrigerating equipment, and filtering machinery, Heating, ventilation and air-conditioning installation work, Installation work of refrigeration equipment, Building Management Systems Tenders in USA, Americas Region and Worldwide
Looking for more tenders like this one in Central-heating equipment, Heat-exchange units, air-conditioning and refrigerating equipment, and filtering machinery, Heating, ventilation and air-conditioning installation work, Installation work of refrigeration equipment, Building Management Systems? With millions of global procurement opportunities and new tenders added daily, Tender Impulse is your gateway to international and local contracting success. Whether you're targeting the Infrastructure and construction sector in USA, or expanding across regions, we provide live, accurate and relevant updates every day.
Our platform sources tenders from national and local government portals, international development and funding agencies, municipal corporations, state authorities, NGOs, education ministries and public-private partnerships.
Daily Tender Updates Across 190+ Countries
Every day we add hundreds of new RFPs, RFQs, EOIs and contract awards across multiple sectors and geographies. This tender from USA is just a sample of what's available right now - there are currently 16,510 live USA tenders to explore.
Search Smarter with CPV and Industry Matching
Each listing is categorised using CPV codes such as 39715210, 42510000, 45331000, 45331231, 42961101, enabling precise filtering by tender type, location, industry, deadline and issuing organisation.
Start Your Tender Journey
Request a free live demo to unlock tenders customised to your sector, country and CPV categories - with alerts, documents and submission support.